From Fiber Optic Connector Cross Sectioning and Analysis observations from “Connector B” notes
Observations: This connector has (1) distinctive fiber fracture at the beginning of the ceramic internal chamfer (photo B.2). I did notice more than usual “epoxy shrinkage” against the walls internally. This shrinkage during the thermal curing contributed to the fiber fracture where a nick fatigued the fiber and the stresses of thermal curing and shrinkage actually separated the fiber at this location. The remaining fiber trapped inside the shaft of the ferrule acted as an anchor point. This is the most common problem created by the nicking of the fiber from the improper use of mechanical strippers or misaligned blades.
READ THE BLOG: Cross Sectioning of Fiber Optic Connectors: the three methods, advantages and disadvantages
Additional resources from the FOC team include:
- Category Resource:
- View the Glossary, Acronyms, Military Specifications for Connectors
- Q&A Resource: email technical questions to AskFOC@focenter.com
Have questions about this FOC Tip?
Contact FOC with questions at: (800) 473-4237 / 508-992-6464 or email: FiberOpticCenter@focenter.com and we will respond ASAP.